Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 20 de 31
Filter
1.
Cardiovasc Intervent Radiol ; 46(3): 327-336, 2023 Mar.
Article in English | MEDLINE | ID: covidwho-2301473

ABSTRACT

PURPOSE: The aim of this study was to analyze the impact of using intra-procedural pre-ablation contrast-enhanced CT prior to percutaneous thermal ablation (pre-ablation CECT) of colorectal liver metastases (CLM) on local outcomes. MATERIALS AND METHODS: This retrospective analysis of a prospectively collected liver ablation registry included 144 consecutive patients (median age 57 years IQR [49, 65], 60% men) who underwent 173 CT-guided ablation sessions for 250 CLM between October 2015 and March 2020. In addition to oncologic outcomes, technical success was retrospectively evaluated using a biomechanical deformable image registration software for 3D-minimal ablative margin (3D-MAM) quantification. Bayesian regression was used to estimate effects of pre-ablation CECT on residual unablated tumor, 3D-MAM, and local tumor progression-free survival (LTPFS). RESULTS: Pre-ablation CECT was acquired in 71/173 (41%) sessions. Residual unablated tumor was present in one (0.9%) versus nine tumors (6.6%) ablated with versus without using pre-ablation CECT, respectively (p = 0.024). Pre-ablation CECT use decreased the odds of residual disease on first follow-up by 78% (CI95% [5, 86]) and incomplete ablation (3D-MAM ≤ 0 mm) by 58% (CI95% [13, 122]). The odds ratio for residual unablated tumor for larger CLM was lower when pre-ablation CECT was used (odds ratio 1.0 with pre-ablation CECT vs. 2.52 without). Pre-ablation CECT use was not associated with improvements on LTPFS. CONCLUSIONS: Pre-ablation CECT is associated with improved immediate outcomes by significantly reducing the incidence of residual unablated tumor and by mitigating the risk of incomplete ablation for larger CLM. We recommend performing baseline intra-procedural pre-ablation CECT as a standard imaging protocol. LEVEL OF EVIDENCE: Level 3 (retrospective cohort study).


Subject(s)
Catheter Ablation , Colorectal Neoplasms , Liver Neoplasms , Male , Humans , Middle Aged , Female , Retrospective Studies , Contrast Media , Bayes Theorem , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/surgery , Liver Neoplasms/pathology , Tomography, X-Ray Computed/methods , Colorectal Neoplasms/pathology , Catheter Ablation/methods , Treatment Outcome
2.
BMC Cardiovasc Disord ; 23(1): 192, 2023 04 13.
Article in English | MEDLINE | ID: covidwho-2303656

ABSTRACT

BACKGROUND: Postcardiac injury syndrome (PCIS) is an easy-to-miss diagnosis, but it is not an uncommon complication. The phenomenon of echocardiography (ECHO) showing both severe pulmonary arterial hypertension (PAH) and severe tricuspid regurgitation (TR) is indeed rare in PCIS after extensive radiofrequency ablation. CASE PRESENTATION: A 70-year-old male was diagnosed with persistent atrial fibrillation. The patient received radiofrequency catheter ablation due to his atrial fibrillation being refractory to antiarrhythmic drugs. After the anatomical three-dimensional models were created, ablations were performed on the left and right pulmonary veins, roof linear and bottom linear of the left atrium, and the cavo-tricuspid isthmus. The patient was discharged in sinus rhythm (SR). After 3 days, he was admitted to the hospital for gradually worsening dyspnea. Laboratory examination showed a normal leukocyte count with an increased percentage of neutrophils. The erythrocyte sedimentation rate, C-reactive protein concentration, interleukin-6, and N-terminal pro-B-type natriuretic peptide were elevated. ECG exhibited SR, V1-V4 of precordial lead P-wave amplitude which was increased but not prolonged, PR segment depression, and ST-segment elevation. Computed tomography angiography of the pulmonary artery revealed that the lung had scattered high-density flocculent flakes and a small amount of pleural and pericardial effusion. Local pericardial thickening was seen. ECHO showed severe PAH with severe TR. Diuretics and vasodilators did not relieve the symptoms. Tumors, tuberculosis, and immune system diseases were all excluded. Considering the patient's diagnosis of PCIS, the patient was treated with steroids. The patient recovered on the 19th day post ablation. The patient's condition was maintained until 2 years of follow-up. CONCLUSIONS: The phenomenon of ECHO showing severe PAH with severe TR is indeed rare in PCIS. Due to the lack of diagnostic criteria, such patients are easily misdiagnosed, leading to a poor prognosis.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Hypertension, Pulmonary , Pulmonary Arterial Hypertension , Tricuspid Valve Insufficiency , Male , Humans , Aged , Pulmonary Arterial Hypertension/diagnosis , Pulmonary Arterial Hypertension/etiology , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/etiology , Tricuspid Valve Insufficiency/surgery , Heart Atria , Hypertension, Pulmonary/surgery , Familial Primary Pulmonary Hypertension , Catheter Ablation/adverse effects , Catheter Ablation/methods , Treatment Outcome
3.
G Ital Cardiol (Rome) ; 24(3): 241-244, 2023 Mar.
Article in Italian | MEDLINE | ID: covidwho-2282393

ABSTRACT

BACKGROUND: This report describes the findings of the 2020 Italian Catheter Ablation Registry of the Italian Association of Arrhythmology and Cardiac Pacing (AIAC). METHODS: Data collection was retrospective. A standardized questionnaire was completed by each of the participating centers. RESULTS: A total of 10 378 ablation procedures were performed by 66 institutions. Most centers (70%) have an electrophysiology laboratory, and 23% a hybrid cardiac surgery laboratory. All centers have a 3D mapping system. The median number of electrophysiologists and nurses involved in the electrophysiology laboratory was 3.5 and 3, respectively. An electrophysiology technician was involved in 35% of all centers. In 88.2% of cases, catheter ablation was performed for supraventricular arrhythmias; the most frequently treated arrhythmia was atrial fibrillation (39.4%), followed by atrioventricular nodal reentrant tachycardia (18.6%), and common atrial flutter (10.6%). In 72.9% of patients, catheter ablation was performed using a 3D mapping system, with a "near-zero" fluoroscopic approach in 37.7% of all patients. CONCLUSIONS: The 2020 Italian Catheter Ablation Registry confirmed that the electrophysiology activity was markedly affected by the COVID-19 pandemic; atrial fibrillation is the most frequently treated arrhythmia with an increasing number of procedures performed with a 3D mapping system and a "near-zero" approach.


Subject(s)
Atrial Fibrillation , COVID-19 , Catheter Ablation , Humans , Atrial Fibrillation/surgery , Pandemics , Retrospective Studies , Registries
5.
Card Electrophysiol Clin ; 14(3): 517-532, 2022 09.
Article in English | MEDLINE | ID: covidwho-2229044

ABSTRACT

"Despite being one of the best understood cardiac arrhythmias, the clinical meaning of atrial flutter varies according to the specific context, and its optimal treatment may be limited by both the suboptimal response to rate/rhythm control drugs and by the complexity of the underlying substrate. In this article, we present a state-of-the-art overview of mechanisms, prognostic impact, and medical/interventional management options for atrial flutter in several specific patient populations, including heart failure, cardiomyopathies, muscular dystrophies, posttransplant patients, patients with respiratory disorders, athletes, and subjects with preexcitation, aiming to stimulate further research in this challenging field and facilitate appropriate patient care."


Subject(s)
Atrial Fibrillation , Atrial Flutter , Cardiomyopathies , Catheter Ablation , Atrial Fibrillation/surgery , Humans
6.
BMC Cardiovasc Disord ; 23(1): 46, 2023 01 25.
Article in English | MEDLINE | ID: covidwho-2214529

ABSTRACT

BACKGROUND: SARS-CoV-2 may trigger both vasculitis and arrhythmias as part of a multisystem inflammatory syndrome described in children as well as in adults following COVID-19 infection with only minor respiratory symptoms. The syndrome denotes a severe dysfunction of one or more extra-pulmonary organ systems, with symptom onset approximately 2-5 weeks after the COVID-19 infection. In the present case, a seemingly intractable ventricular tachycardia preceded by SARS-CoV2 infection was only managed following the diagnosis and management of aortitis. CASE PRESENTATION: A 69-year-old woman was hospitalized due to syncope, following a mild COVID-19 infection. She presented with paroxysmal atrial fibrillation and intermittent ventricular tachycardia interpreted as a septum-triggered bundle branch reentry ventricular tachycardia, unaffected by amiodaron, lidocaine and adenosine. A CT-scan revealed inflammation of the aortic arch, extending into the aortic root. In the following days, the tachycardia progressed to ventricular storm with intermittent third-degree AV block. A temporary pacemaker was implanted, and radiofrequency ablation was performed to both sides of the ventricular septum after which the ventricular tachycardia was non-inducible. Following supplemental prednisolone treatment, cardiac symptoms and arrythmia subsided, but recurred after tapering. Long-term prednisolone treatment was therefore initiated with no relapse in the following 14 months. CONCLUSION: We present a rare case of aortitis complicated with life-threatening ventricular tachycardia presided by Covid-19 infection without major respiratory symptoms. Given a known normal AV conduction prior to the COVID-19 infection, it seems likely that the ensuing aortitis in turn affected the septal myocardium, enabling the reentry tachycardia. Generally, bundle branch reentry tachycardia is best treated with radiofrequency ablation, but if it is due to aortitis with myocardial affection, long-term anti-inflammatory treatment is mandatory to prevent relapse and assure arrhythmia control. Our case highlights importance to recognize the existence of the multisystem inflammatory syndrome in adults (MIS-A) following COVID-19 infection in patients with alarming cardiovascular symptoms. The case shows that the early use of an CT-scan was crucial for both proper diagnosis and treatment option.


Subject(s)
Aortitis , COVID-19 , Catheter Ablation , Tachycardia, Ventricular , Adult , Aged , Child , Female , Humans , Aortitis/diagnosis , Aortitis/therapy , Aortitis/virology , COVID-19/complications , Electrocardiography , RNA, Viral , SARS-CoV-2 , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/therapy
8.
Rev Esp Cardiol (Engl Ed) ; 75(12): 1029-1039, 2022 Dec.
Article in English, Spanish | MEDLINE | ID: covidwho-2076671

ABSTRACT

INTRODUCTION AND OBJECTIVES: The results of the 2021 Spanish catheter ablation registry are presented. METHODS: Data collection was carried out retrospectively by filling in and sending a specific form by the participating centers. RESULTS: Data from 93 centers (65 public, 28 private) were analyzed. A total of 17941 ablation procedures were reported with a mean of 193 ± 133 cases per centre. Recovery of activity from SARS-CoV-2 pandemic lockdown has led to a notable increase in the number of procedures (+2772 procedures, +18%) despite a small decrease in participating centers (4 centers less than in 2020). Atrial fibrillation ablation continues to be the leading procedure, with 5848 procedures (32,6%). Together with ablation of the cavotricuspid isthmus (3766; 21%) and atrioventricular nodal reentrant tachycardia (3132; 17,5%) they constitute the 3 most frequently approached substrates. The total success rate reported (94%) is similar to previous years with a similar rate of complications (2%) and mortality (0.07). A total of 401 procedures were performed in pediatric patients (3,8%). CONCLUSIONS: The Spanish catheter ablation registry systematically and continuously collects the national activity, which has recovered significantly from the SARS-CoV-2 pandemic impact in 2020. Success rate for 2021 remains high, with a low complication rate.


Subject(s)
Atrial Fibrillation , COVID-19 , Cardiology , Catheter Ablation , Humans , Child , Retrospective Studies , SARS-CoV-2 , COVID-19/epidemiology , Communicable Disease Control , Registries , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery
10.
BMJ Case Rep ; 15(8)2022 Aug 02.
Article in English | MEDLINE | ID: covidwho-1992986

ABSTRACT

We present a rare complication of microwave ablation (MWA) in a male patient in his 80s. His massive pulmonary necrosis and tension pneumothorax required urgent surgery. However, the damage to the lung tissue was too large, deep and fragile. We failed to suture or conduct wedge resection on the lung lesion, so, left upper lobectomy was necessary. Therefore, we suggest that it is probably possible to reduce the frequency and time threshold when performing MWA for the elderly with comorbidities.


Subject(s)
Catheter Ablation , Lung Neoplasms , Aged , Aged, 80 and over , Catheter Ablation/adverse effects , Humans , Lung/diagnostic imaging , Lung/pathology , Lung/surgery , Lung Neoplasms/pathology , Lung Neoplasms/surgery , Male , Microwaves/adverse effects , Necrosis/etiology , Necrosis/surgery , Octogenarians
11.
Open Heart ; 9(1)2022 06.
Article in English | MEDLINE | ID: covidwho-1891894

ABSTRACT

OBJECTIVE: Atrial fibrillation (AF) ablation services were significantly affected by the COVID-19 pandemic. We aimed to evaluate a symptom-based clinician prioritisation scheme for waiting list management compared with patient-completed quality of life (QoL) scores. We also sought to understand factors influencing QoL, particularly the impact of COVID-19, on patients awaiting AF ablation, via a bespoke questionnaire. METHODS: Patients awaiting AF ablation were sent two QoL questionnaires (Atrial Fibrillation Effect on QualiTy of Life (AFEQT) and EuroQol 5D (EQ5D-5L)) and the bespoke questionnaire. At a separate time point, patients were categorised as C1-urgent, C2-priority or C3-routine by their cardiologist based on review of clinic letters. RESULTS: There were 118 patients included with priority categorisation available for 86 patients. Median AFEQT scores were lower in C2 (30.4; 17.2-51.9) vs C3 patients (56.5; 32.1-74.1; p<0.01). Unplanned admission occurred in 3 patients in C3 with AFEQT scores of <40. Although 65 patients had AF symptoms during the pandemic, 43.1% did not seek help where they ordinarily would have. An exercise frequency of ≥3-4 times a week was associated with higher AFEQT (56.5; 41.2-74.1; p<0.001) and EQ5D (0.84; 0.74-0.88; p<0.0001) scores. CONCLUSION: The QoL of patients awaiting AF ablation is impaired and AFEQT helps to identify patients at risk of admission, over and above physician assessment. COVID-19 influenced patients seeking medical attention with symptomatic AF when they normally would. Regular exercise is associated with better QoL in patients awaiting AF ablation.


Subject(s)
Atrial Fibrillation , COVID-19 , Catheter Ablation , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Humans , Pandemics , Quality of Life
12.
Am J Surg ; 224(1 Pt B): 408-411, 2022 07.
Article in English | MEDLINE | ID: covidwho-1664641

ABSTRACT

BACKGROUND: Ethanol ablation (EA) is a non-surgical option for the treatment of benign cystic thyroid nodules. This study summarizes our preliminary experience with the efficacy and safety of EA. METHODS: A retrospective analysis was performed of patients undergoing EA for symptomatic, benign, cystic and predominantly cystic (≥75%) thyroid nodules. Baseline nodule volume, cosmetic scores, and symptom scores were assessed, as well as volume reduction ratio (VRR), cosmetic and symptom scores at post-procedure months 1, 3, 6, and 12. RESULTS: 31 patients underwent an uncomplicated EA for a single cyst with an average volume of 21.3 cc (range: 1.7-101.4 cc). Follow-up was limited by the COVID-19 pandemic. Mean nodule VRRs were 66 ± 20% (1 m, n = 17), 87 ± 15% (3 m, n = 9), 72 ± 20% (6 m, n = 7), and 78% (12 m, n = 3). Mean symptom and cosmetic scores decreased concurrently post-procedure. CONCLUSION: EA is a safe, effective option for benign cystic and predominantly cystic thyroid nodules.


Subject(s)
COVID-19 , Catheter Ablation , Thyroid Nodule , Catheter Ablation/methods , Ethanol/therapeutic use , Humans , Pandemics , Retrospective Studies , Thyroid Nodule/surgery , Treatment Outcome
13.
Card Electrophysiol Clin ; 14(1): 1-9, 2022 03.
Article in English | MEDLINE | ID: covidwho-1635014

ABSTRACT

COVID-19 mainly affects the respiratory system but has been correlated with cardiovascular manifestations such as myocarditis, heart failure, acute coronary syndromes, and arrhythmias. Cardiac arrhythmias are the second most frequent complication affecting about 30% of patients. Several mechanisms may lead to an increased risk of cardiac arrhythmias during COVID-19 infection, ranging from direct myocardial damage to extracardiac involvement. The aim of this review is to describe the role of COVID-19 in the pathogenesis of cardiac arrhythmias and provide a comprehensive guidance for their monitoring and management.


Subject(s)
Atrial Fibrillation , Atrial Flutter , COVID-19 , Catheter Ablation , Tachycardia, Supraventricular , Atrial Fibrillation/surgery , COVID-19/complications , Catheter Ablation/adverse effects , Humans , Prevalence , SARS-CoV-2
14.
Clin Mol Hepatol ; 27(4): 564-574, 2021 10.
Article in English | MEDLINE | ID: covidwho-1551487

ABSTRACT

BACKGROUND/AIMS: In July 2017, the Emprint™ next-generation microwave ablation system using thermosphere technology (Covidien, Boulder, CO, USA) was approved for use in Japan. This system can produce a predictable spherical ablation zone at higher temperatures than radiofrequency ablation (RFA). The aim of the present study was to elucidate whether this new microwave thermosphere ablation (MTA) could safely improve outcome compared to RFA, which is the standard of care for small hepatocellular carcinoma (HCC). METHODS: This retrospective study analyzed 513 patients with 630 HCCs (≤3 cm) who were performed by percutaneous RFA (174 patients, 214 HCCs) or MTA (339 patients, 416 HCCs) between January 2016 and March 2020. RESULTS: Median ablation time was significantly shorter for MTA (240 seconds) than for RFA (721 seconds; P<0.001). A significant difference in 3-year local tumor progression rate was evident between the RFA group (22%) and MTA group (8%; P<0.001). Multivariable analysis revealed ablation procedure and tumor diameter as independent factors contributing to local tumor progression (MTA; P<0.001; hazard ratio, 0.565; 95% confidence interval, 0.437-0.731). In patients with primary HCC, a significant difference in overall survival was evident (RFA vs. MTA, 3-year, 77% vs. 95%, P=0.029). Ablation procedure and Child-Pugh score were independent factors contributing to survival. The total complication rate was significantly lower for MTA (8%) than for RFA (14%, P<0.05), particularly for bile duct injury (3% vs. 9%, respectively; P<0.05). CONCLUSION: Next-generation MTA for small HCC could provide safer, more curative treatment in a shorter ablation time than RFA.


Subject(s)
Carcinoma, Hepatocellular , Catheter Ablation , Liver Neoplasms , Radiofrequency Ablation , Carcinoma, Hepatocellular/diagnosis , Carcinoma, Hepatocellular/surgery , Humans , Liver Neoplasms/diagnosis , Liver Neoplasms/surgery , Microwaves , Radiofrequency Ablation/adverse effects , Retrospective Studies , Treatment Outcome
15.
Rev Esp Cardiol (Engl Ed) ; 74(12): 1072-1083, 2021 Dec.
Article in English, Spanish | MEDLINE | ID: covidwho-1510233

ABSTRACT

INTRODUCTION AND OBJECTIVES: This article reports the results of the 2020 Spanish Catheter Ablation Registry, a year marked by the SARS-CoV-2 pandemic. METHODS: Data were collected retrospectively through completion and return of a specific form by the participating centers. RESULTS: Data from 97 centers (67 public, 30 private) were analyzed. A total of 15 169 ablation procedures were reported with a mean of 155±117 and a median [interquartile range] of 115 [62-227]. Because of the SARS-CoV-2 pandemic, both procedures and participating centers markedly decreased (-3380 procedures,-18%) and there were 5 centers less than in 2019. The most common procedure continued to be atrial fibrillation ablation (4513; 30%), well ahead of the remaining substrates, followed by ablation of the cavotricuspid isthmus (3188; 21%), and intranodal re-entry tachycardia (2808; 18%). Ablation of these 3 substrates continued to form the bulk of the procedures. The total success rate was slightly lower than in previous years (88%) with a similar complication rate (n=309; 2%) and mortality (n=7; 0.04%). A total of 243 procedures were performed in pediatric patients (1.6%). CONCLUSIONS: The Spanish Catheter Ablation Registry systematically and continuously reflects the national trajectory, which, in 2020, was markedly affected by the SARS-CoV-2 pandemic. Although slightly lower than in previous years, the success rate remained high, with a low complication rate.


Subject(s)
Atrial Fibrillation , COVID-19 , Cardiology , Catheter Ablation , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Child , Humans , Registries , Retrospective Studies , SARS-CoV-2
17.
J Vasc Surg Venous Lymphat Disord ; 9(3): 676-682.e2, 2021 05.
Article in English | MEDLINE | ID: covidwho-1454341

ABSTRACT

BACKGROUND: Iliac vein compression (IVC) is a common condition in patients with varicose veins (VVs) of the legs. IVC has been classified into three grades in previous studies. Grade II IVC is defined by >50% stenosis without the development of collateral circulation. The purpose of the present study was to investigate the outcomes of radiofrequency ablation (RFA) for patients with VVs combined with grade II IVC. METHODS: A retrospective analysis was conducted of 339 patients who had undergone RFA for VVs of the left leg from March 2017 to January 2019. Duplex ultrasonography, computed tomography venography, and venography were performed to evaluate for grade II IVC. All the patients were divided into two groups. Group 1 included patients with VVs only, and group 2, patients with VVs combined with grade II IVC. Propensity score matching was used to ensure an even distribution of confounding factors between groups. The venous clinical severity score (VCSS) and chronic venous insufficiency questionnaire (CIVIQ) score were recorded during the 12-month follow-up. Occlusion of the truncal veins was evaluated using duplex ultrasound scans. RESULTS: Using 1:1 propensity score matching, 50 pairs of patients were enrolled in the present analysis. The average age of groups 1 and 2 was 58.7 ± 13.1 and 60.1 ± 7.1 years, respectively. The VCSS had decreased significantly from baseline to 12 months postoperatively (group 1, from 5 to 1; group 2, from 4 to 1; P < .01). A significant increase in the CIVIQ score was found between the baseline and 12-month evaluations for both groups (group 1, from 62.5 to 69; group 2, from 63 to 70; P < .01). The truncal occlusion rate was 98% in both groups at 12 months. No significant differences were found between the two groups in the VCSS, CIVIQ score, procedure complications, or occlusion rate during the 12-month follow-up. CONCLUSIONS: RFA is effective for patients with VVs combined with grade II IVC.


Subject(s)
Catheter Ablation , Iliac Vein/physiopathology , May-Thurner Syndrome/physiopathology , Saphenous Vein/surgery , Varicose Veins/surgery , Vascular Patency , Venous Insufficiency/surgery , Adult , Aged , Catheter Ablation/adverse effects , Constriction, Pathologic , Female , Humans , Iliac Vein/diagnostic imaging , Ligation , Male , May-Thurner Syndrome/diagnostic imaging , Middle Aged , Recurrence , Retrospective Studies , Risk Factors , Saphenous Vein/diagnostic imaging , Saphenous Vein/physiopathology , Sclerotherapy , Severity of Illness Index , Time Factors , Treatment Outcome , Varicose Veins/diagnostic imaging , Varicose Veins/physiopathology , Venous Insufficiency/diagnostic imaging , Venous Insufficiency/physiopathology
18.
Lasers Surg Med ; 53(3): 370-376, 2021 03.
Article in English | MEDLINE | ID: covidwho-1453619

ABSTRACT

BACKGROUND AND OBJECTIVES: Temperature-controlled radiofrequency inferior turbinate ablation (TCRFA) uses a feedback system to control thermal injury and achieve precise volumetric heating to induce specific scar formation. However, it requires costly single-use proprietary consumables. Comparable volumetric tissue heating may be achieved for a fraction of the cost by adjusting the power settings on traditional monopolar electrosurgery devices that use low-cost needle tips. This pre-clinical study aims to determine the optimized power parameters to achieve electrosurgical coagulum volume similar to that of TCRFA. STUDY DESIGN/MATERIALS AND METHODS: An electrosurgery submucosal diathermy (SMD) system (cut mode, 4-32 W, 5-120 seconds) and a temperature-controlled radiofrequency ablation system (standard clinical parameters for treating inferior turbinate hypertrophy) were used to coagulate egg white and chicken breast. Coagulum major and minor axis were measured, and lesion volume was approximated as prolate spheroid. RESULTS: No significant difference in volume was found between the temperature-controlled system and the electrosurgery system at 8 W for 30 seconds, 8 W for 60 seconds, 16 W for 30 seconds, 32 W for 5 seconds, and 32 W for 15 seconds. The time to achieve equivalent lesion size was significantly less in the SMD system when compared to the temperature-controlled system (P < 0.05). CONCLUSION: Electrosurgery handpieces may achieve similar lesion volume effects as the temperature feedback-controlled, single-use handpieces when set to the optimized parameters. SMD handpieces are significantly more cost and time effective than proprietary devices, and they are easily used in the office. SMD devices may be a more affordable alternative to temperature-controlled systems with comparable lesion volume effect and may be valuable for office-based therapy. Lasers Surg. Med. © 2020 Wiley Periodicals LLC.


Subject(s)
Catheter Ablation , Diathermy , Electrosurgery , Feedback , Heating , Turbinates/surgery
20.
J Cardiovasc Electrophysiol ; 32(12): 3125-3134, 2021 12.
Article in English | MEDLINE | ID: covidwho-1373828

ABSTRACT

BACKGROUND: Transesophageal echocardiography (TEE) is variably performed before atrial fibrillation (AF) ablation to evaluate left atrial appendage (LAA) thrombus. We describe our experience with transitioning to the pre-ablation cardiac computed tomography (CT) approach for the assessment of LAA thrombus during the COVID-19 pandemic. METHODS: We studied consecutive patients undergoing AF ablation at our center. The study cohort was divided into pre- versus post-COVID groups. The pre-COVID cohort included ablations performed during the 1 year before the COVID-19 pandemic; pre-ablation TEE was used routinely to evaluate LAA thrombus in high-risk patients. Post-COVID cohort included ablations performed during the 1 year after the COVID-19 pandemic; pre-ablation CT was performed in all patients, with TEE performed only in patients with LAA thrombus by CT imaging. The demographics, clinical history, imaging, and ablation characteristics, and peri-procedural cerebrovascular events (CVEs) were recorded. RESULTS: A total of 637 patients (pre-COVID n = 424, post-COVID n = 213) were studied. The mean age was 65.6 ± 10.1 years in the total cohort, and the majority were men. There was a significant increase in pre-ablation CT imaging from pre- to post-COVID cohort (74.8% vs. 93.9%, p ≤ .01), with a significant reduction in TEEs (34.6% vs. 3.7%, p ≤ .01). One patient in the post-COVID cohort developed CVE following negative pre-ablation CT. However, the incidence of peri-procedural CVE between both cohorts remained statistically unchanged (0% vs. 0.4%, p = .33). CONCLUSION: Implementation of pre-ablation CT-only imaging strategy with selective use of TEE for LAA thrombus evaluation is not associated with increased CVE risk during the COVID-19 pandemic.


Subject(s)
Atrial Appendage , Atrial Fibrillation , COVID-19 , Catheter Ablation , Thrombosis , Aged , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Echocardiography, Transesophageal , Female , Humans , Incidence , Male , Middle Aged , Pandemics , SARS-CoV-2 , Thrombosis/diagnostic imaging , Thrombosis/epidemiology , Tomography
SELECTION OF CITATIONS
SEARCH DETAIL